This single-center retrospective study compared NIRS-guided selective distal perfusion catheter placement in 83 adults receiving femoral VA-ECMO with routine prophylactic placement in 27. ECPR accounted for 64.5% of the population. With selective placement, 45/83 patients avoided catheter placement (54.2%; exact 95% CI, 42.9–65.2%), with no clinically overt limb ischemia among these 45 (exact 95% CI, 0–7.9%). Limb ischemia occurred in 2/83 selective-strategy patients versus 2/27 prophylactic-strategy patients (2.4% versus 7.4%; risk difference, −5.0 percentage points; 95% CI, −21.1 to +3.0; p = 0.252).
Selective NIRS-guided catheter placement was feasible in this ECPR-dominant cohort. The findings do not establish equivalent limb ischemia risk or definitive safety compared with routine prophylactic placement.
Study limitation: The single-center retrospective design and imprecise limb ischemia estimates limit comparative conclusions; protocol-triggered catheter placement also prevents independent assessment of threshold accuracy.