← All research

Limited Discrimination of Risk Scores for Right Ventricular Failure After Left Ventricular Assist Device Implantation.

ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026-11-20

Tomoki Sakata, Patrick Hong, Kent Shively et al.

A retrospective single-center study evaluated prediction of right ventricular failure in 331 patients undergoing centrifugal-flow LVAD implantation between 2011 and 2025. INTERMACS-defined right ventricular failure occurred in 105 patients (31.7%). Although EUROMACS, Utah, and STOP-RVF scores were associated with failure, discrimination was modest, with areas under the curve around 0.70. Performance remained modest in the HeartMate 3 subgroup and when postoperative right-sided mechanical support was the endpoint. Published risk strata also failed to consistently reproduce their original absolute event rates.

Clinical bottom line

Established scores showed limited ability to distinguish patients who developed right ventricular failure after centrifugal-flow LVAD implantation. These findings highlight uncertainty in individual risk estimates and transportability of published risk strata.

Study limitation: The retrospective, single-center design limits generalizability; discrimination estimates were reported without confidence intervals in the abstract.

Read the original on PubMed

AI-generated from the published abstract with automated source checks. For research discovery; consult the original paper before applying findings.