← All research

Near-Infrared Spectroscopy-Guided Selective Distal Perfusion in Femoral Venoarterial Extracorporeal Membrane Oxygenation: A Feasibility Study.

Diagnostics (Basel, Switzerland) · 2026-10-15

Woong-Su Yoon, Yerin Kim, Ju-Seung Kwun et al.

This single-center retrospective study compared NIRS-guided selective distal perfusion catheter placement in 83 adults receiving femoral VA-ECMO with routine prophylactic placement in 27. ECPR accounted for 64.5% of the population. With selective placement, 45/83 patients avoided catheter placement (54.2%; exact 95% CI, 42.9–65.2%), with no clinically overt limb ischemia among these 45 (exact 95% CI, 0–7.9%). Limb ischemia occurred in 2/83 selective-strategy patients versus 2/27 prophylactic-strategy patients (2.4% versus 7.4%; risk difference, −5.0 percentage points; 95% CI, −21.1 to +3.0; p = 0.252).

Clinical bottom line

Selective NIRS-guided catheter placement was feasible in this ECPR-dominant cohort. The findings do not establish equivalent limb ischemia risk or definitive safety compared with routine prophylactic placement.

Study limitation: The single-center retrospective design and imprecise limb ischemia estimates limit comparative conclusions; protocol-triggered catheter placement also prevents independent assessment of threshold accuracy.

Read the original on PubMed